Refer to the exhibit.
The interface remains in a down state after entering the command that is shown in the exhibit. What is the cause of the problem?
A. The feature interface-vlan command must be configured.
B. The VDC contains only F1 interfaces.
C. There are IP address conflicts.
D. The VDC is “type OTV.”
E. The command copy run start was not entered.
Correct Answer: B
Explanation/Reference:
Explanation:
Starting with Cisco NX-OS Release 6.2(2), we do not support the interoperability of F1 and F2 Series modules in any VDC, either in a dedicated mode or in a shared mode. If you have configured F1 and F2 Series modules as supported line cards in a storage VDC during an In-Service Software Upgrade (ISSU) to Cisco NX-OS Release 6.2(2) or later releases, before ISSU, reconfigure your storage VDC by using the limit-resource module-type command to avoid any unnecessary disruption to the system.