Home » HP » HP0-J64 » Which condition result in an Persistent Port failover on an HP 3PAR StoreServ array at In Farm OS level 3.1.3?
Which condition result in an Persistent Port failover on an HP 3PAR StoreServ array at In Farm OS level 3.1.3? (Select two)
A. Automatic master node assignment change
B. RSCN event after zone set update
C. Loss of port sync
D. User directed Host Persona Change
E. Node Reboot or spontaneous failure
Correct Answer: BD
Explanation/Reference:
Explanation:
Fabric zoning controls which FC end-devices have access to each other on the fabric. Zoning also isolates the host and HP 3PAR StoreServ Storage ports from Registered State Change Notifications (RSCNs) that are irrelevant to these ports
When changing an existing host persona from 6 to 11, a host reboot is required tor the change to take effect. This is an offline process. See "Configuring ESX/ESXi Multipathing for Round Robin via SATP PSP" (page 42) for the detailed procedure, as the host persona change should coincide with changing the SATP rules on the host as well.
Download Printable PDF. VALID exam to help you PASS.
|
|