Refer to the exhibit.
Each ESXi host has three NICs assigned to a virtual switch.
Which Network Failure Detection Policy will prevent network failover?
A. Notify Switches Policy
B. Link status only
C. Failback Policy
D. Beacon probing
Refer to the exhibit.
Each ESXi host has three NICs assigned to a virtual switch.
Which Network Failure Detection Policy will prevent network failover?
A. Notify Switches Policy
B. Link status only
C. Failback Policy
D. Beacon probing
Question is about to prevent failover , not to make failover happen . Incase of 03 or more NICs beacon probing is used for failover purpose . B is correct ans .
link status does not detect the following configuration errors:
Pulled cable that connects a physical switch to another networking devices, for example, an upstream switch .
Fully agree.
It cannot be B Link Status only since it does not detect “Pulled cable that connects a physical switch to another networking devices, for example, an upstream switch .”
I think it is D – Beacon probing.
I Think D
https://docs.vmware.com/en/VMware-vSphere/6.7/com.vmware.vsphere.networking.doc/GUID-4D97C749-1FFD-403D-B2AE-0CD0F1C70E2B.html