Which setting in the WLC must be disabled before the floor calibration is started?

A wireless engineer is calibrating a floor using Cisco Prime Infrastructure. Which setting in the WLC must be disabled before the floor calibration is started?
A. CleanAir
B. Dynamic Channel Assignment
C. Coverage Hole Detection
D. Tx Power Control

cisco-exams

4 thoughts on “Which setting in the WLC must be disabled before the floor calibration is started?

  1. Seems D is the answer. From page 5-61 of https://www.cisco.com/c/en/us/td/docs/solutions/Enterprise/Mobility/WiFiLBS-DG.pdf

    Temporarily disable Dynamic Transmit Power Control (DTPC) prior to conducting calibration data
    collection. DTPC must be disabled separately for each band using either the controller GUI, the
    controller CLI or WCS for each controller whose registered access points are expected to participate
    in calibration data collection. After calibration data collection has been performed, DTPC should
    be re-enabled for normal production operation