Which two chassis discovery policy settings allow far a UCS chassis to be connected to a pair of Fabric Interconnect using only two physical connections?

Which two chassis discovery policy settings allow far a UCS chassis to be connected to a pair of Fabric Interconnect using only two physical connections? (Choose two)
A. 4-link
B. 2-link
C. 8-link
D. 1-link
E. Platform-max

cisco-exams

2 thoughts on “Which two chassis discovery policy settings allow far a UCS chassis to be connected to a pair of Fabric Interconnect using only two physical connections?

  1. You must assume UCS Manager version 2.x or lower:
    https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-0/b_UCSM_GUI_Configuration_Guide_2_0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_01100.html

    Table 1: 1 link between IOM and fabric interconnects
    1-Link Chassis Discovery Policy = Chassis is discovered by Cisco UCS Manager and added to the Cisco UCS domain as a chassis wired with 1 link.
    Platform-Max Discovery Policy = Chassis is discovered by Cisco UCS Manager and added to the Cisco UCS domain as a chassis wired with 1 link.
    All other Discovery Polices = Chassis cannot be discovered by Cisco UCS Manager and is not added to the Cisco UCS domain.

    This behavior changed with UCS Manager v3.x and Platform-Max would not be valid.