HP5-T01D Exam and Free Practice Test - VCEguide
Skip to content
  • Support
  • TERMS OF SERVICES
  • DMCA – Copyrights
  • About
Share The Experience - Real Exam Questions

microsoft-exams

  • Cisco
  • Microsoft
  • CompTIA
  • VMware
  • Oracle
  • Amazon
  • Juniper
  • Checkpoint
  • Exin
  • HP
  • IBM
  • Citrix
  • –View ALL–

Questions

  • Question 1
  • Question 2
  • Question 3
  • Question 4
  • Question 5
  • Question 6
  • Question 7
  • Question 8
  • Question 9
  • Question 10
  • Question 11
  • Question 12
  • Question 13
  • Question 14
  • Question 15
  • Question 16
  • Question 17
  • Question 18
  • Question 19
  • Question 20
  • Question 21
  • Question 22
  • Question 23
  • Question 24
  • Question 25
  • Question 26
  • Question 27
  • Question 28
  • Question 29
  • Question 30

HP5-T01D

Which tool can report the amount of life remaining in an HP solid state drive (SSD)?

05/21/2017 – by Mod_GuideK 0

Which tool can report the amount of life remaining in an HP solid state drive (SSD)? A. Array Diagnostic Utility B. SMARTSSD Wear Guage C. Storage Management Utility D. Intelligent Provisioning

What should you check to verify that the physical hardware connectivity is connected?

05/21/2017 – by Mod_GuideK 0

After you replace the system board in ProLiant BL460c GB server blade, the server cannot connect to an external shared storage through the SAS interface. Other similar servers in the same enclosure are in working condition. What should you check…

Which tool can you use to verify that SNMP events appear in HP SIM from a server blade running Windows 2008?

05/21/2017 – by Mod_GuideK 0

Which tool can you use to verify that SNMP events appear in HP SIM from a server blade running Windows 2008? A. Integrated Lights-Out B. HP SNMP Agent C. Onboard Administrator D. System Management Homepage

Which HP tools should you use to determine that an SSD drive has degraded as a result of a large number of write operations?

05/21/2017 – by Mod_GuideK 0

Which HP tools should you use to determine that an SSD drive has degraded as a result of a large number of write operations? (Select three.) A. Array Configuration Utility (ACU) B. SmartSSD Wear Guage C. Array Diagnostic Utility (ADU)…

What should the customer use to meet these requirements?

05/21/2017 – by Mod_GuideK 0

A customer needs to remotely monitor the UPS devices on their network They need to send alert traps to HP Systems Insight Manager (HP SIM) and other SNMP management programs and generate detailed system logs. What should the customer use…

Which RAID level allows the data to be striped across multiple RAIDs?

05/21/2017 – by Mod_GuideK 0

Which RAID level allows the data to be striped across multiple RAIDs? (Select two.) A. RAID 0 B. RAID 1 C. RAID 5 D. RAID 50 E. RAID 60

What are some general requirements that must be met to update Virtual Connect firmware?

05/21/2017 – by Mod_GuideK 0

What are some general requirements that must be met to update Virtual Connect firmware? (Select three.) A. The correct deployment order must be set. B. The VC domains must not be in Maintenance Mode, so the firmware updates have direct…

Which rules for DIMM installation must the engineer follow during this installation?

05/21/2017 – by Mod_GuideK 0

A support engineer is installing DIMMs of different speeds and voltages in a ProLiant DL380p Gen8 Server. Which rules for DIMM installation must the engineer follow during this installation? A. UDIMMs, RDIMMs, and LRDIMMs may be mixed in the same…

What must you do before physically replacing the module?

05/21/2017 – by Mod_GuideK 0

An HP VC Flex-10 module must be replaced in a c3000 BladeSystem enclosure because one uplink port is defective. What must you do before physically replacing the module? A. Back up the enclosure EBIPA information. B. Copy the VCM logs…

Where is the data written when power is lost on an HP Smart Array controller?

05/21/2017 – by Mod_GuideK 0

Where is the data written when power is lost on an HP Smart Array controller? A. network controller B. master boot record C. system memory D. flash backed write cache

Posts navigation

1 2 3 Next

PDF to VCEplus

Top Popular Questions

Download PDF files for FREE

©2023 VCEguide Team.