Home » IBM » C9530-001 » When running messages through the Integration flow, nothing gets recorded into the database. What could be the missing step in the configuration of the message flow?
An IBM Integration Bus Administrator has configured the configurable services DataCaptureStore, DataCaptureSource and DataDestination and ensured the WebUI users are setup correctly. However, when running messages through the Integration flow, nothing gets recorded into the database. What could be the missing step in the configuration of the message flow?
A. The Integration flow was not started.
B. The Integration flow was not deployed.
C. The monitoring events were not created/enabled.
D. The recording was not enabled using the command mqsichangeflowrecording.
Correct Answer: C
Explanation/Reference:
To configure monitoring on a message flow to emit events for capture, use one of the following methods.
Configure and enable event sources, and activate monitoring for the message flow, by completing the steps in Business-level monitoring.
Configure monitoring event sources by using the sample monitoring profile that is provided at install_dir/sample/RecordReplay/basicMonitoringProfile.xml.
References: https://www.ibm.com/support/knowledgecenter/en/SSMKHH_9.0.0/com.ibm.etools.mft.doc/bj23700_.htm