Home » Network Appliance » NS0-520 » Where would you validate this configuration?
After performing failover testing on a newly deployed MetroCluster configuration, some aggregates remain in a degraded state. Referring to the exhibit, which statement is true?
A. The MetroCluster Tiebreaker software is misconfigured
B. The ONTAP Mediator service is misconfigured
C. A cluster switch is powered off
D. A disk shelf is powered off
Answer: D
Explanation:
The aggregate with drives on the powered-off shelf should have a degraded RAID status, and drives on the affected plex should have a failed status You can find more information on this link:
https://docs.netapp.com/us-en/ontap-metrocluster/installip/task_test_the_mcc_configuration.html#verifying-operation-after-loss-of-a-single-storage-shelf
Download Printable PDF. VALID exam to help you PASS.
|
|