Refer to the exhibit. Which three steps must be taken to add NFS storage to the Cisco UCS domain? (Choose3)
A. Configure fabric interconnect A and B to Ethernet switching mode.
B. Configure Eth1/17 as a unified storage port.
C. Configure Eth1/17 as an appliance port.
D. Configure a QoS policy for NFS storage.
E. Create a LAN cloud VLAN on fabric A and fabric B.
F. Create an appliance VLAN on fabric A and fabric B.
Agree with CEF.
CEF
When you create a new appliance VLAN, its IEEE VLAN ID is not added to the LAN Cloud. Therefore, appliance ports that are configured with the new VLAN remain down, by default, due to a pinning failure. To bring up these appliance ports, you have to configure a VLAN in the LAN Cloud with the same IEEE VLAN ID.
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Storage-Mgmt/3-1/b_UCSM_GUI_Storage_Management_Guide_3_1/b_UCSM_GUI_Storage_Management_Guide_3_1_chapter_01100.html#task_8B56D6B9A1084BA6B5BFD18DDD9D13B4
Thanks Jill